Spectroradiometer for Measuring Natural and Artificial Solar Radiation
UV-visible-NIR spectroradiometers with accessories for measuring solar radiation - natural daylight and solar simulators
The precise measurement of natural solar radiation is an important requirement for atmospheric research like for instance the measurement of the Total Ozone Column (TOC) and the determination of UV index. Additionally, renewable energy research and the use of artificial sources such as solar simulators require accurate optical radiation measurement data.
For these types of measurements, very high demands are placed on the measurement systems. In addition to the immensely important reliability, since the measurement locations are often difficult to reach or rarely visited, an enormously wide temperature range, stability of the calibration (absolute as well as wavelength) and highest precision in general are the basic requirements.
We have been an active partner of the solar community since 1986 as both a manufacturer of measuring instruments and a service provider.
Spectroradiometers for measuring solar radiation - natural daylight and solar simulators
Model | Image | Wavelength range /nm | Optical Bandwidth | Measurement range - Spectral sensor | Remark | |
---|---|---|---|---|---|---|
BTS2048-UV-S-WP |
(190 - 430) nm |
0.8 nm |
(3E-5 - 3E4) W/(m²nm) @325nm *6*7 |
for outdoor use (UV spectral range) | ||
BTS2048-VL-TEC-WP |
(280 -1050) nm |
2 nm |
(1E-6 - 1E5) W/(m²nm) *6*7 |
for outdoor use (extended VIS spectral range) | ||
BTS2048-IR-WP |
(950 -2150) nm |
9 nm |
for outdoor use (IR spectral range) | |||
BTS-Solar | Direct spectral irradiance measurement system for e.g. TOC measurements. |
Spectroradiometer for measuring the UV-VIS-NIR spectral irradiance of solar simulators
Model | Image | Entrance optic | Wavelength range / nm | Optical bandwidth | Measurement range - Spectral sensor | Measurement range - Broadband sensor | Remark | |
---|---|---|---|---|---|---|---|---|
SST-1800 Series | Cosine diffuser with quartz dome | SST-1801 (280 - 3000) nm SST-1802 (200 - 3000) nm SST-1803 (280 - 2150) nm | ||||||
BTS2048-UV-S | 10 mm Ø Cosine diffuser f2 ≤ 3% |
(190 - 430) nm |
0.8 nm |
(3E-5 - 3E4) W/(m²nm) @325nm *6*7 |
(5E-3 - 2E5) W/m² | UV spectral range | ||
BTS2048-VL-TEC | 10 mm Ø Cosine diffuser f2 ≤ 3% |
(280 -1050) nm |
2 nm |
(1E-6 - 1E5) W/(m²nm) *6*7 |
0.1 lx - 3E8 lx | extended VIS spectral range | ||
BTS2048-IR | 10 mm Ø Cosine diffuser f2 ≤ 3% |
(950 -2150) nm |
9 nm |
IR spectral range |